| Nemtek Energizer Brand |
Druid |
Wizord |
Merlin |
Merlin Stealth |
Stealth Master |
| Model Number |
13 LCD |
15 LCD |
18 LCD |
114 LCD |
2 |
4 |
4 |
M15S |
M18S |
M25S |
M28S |
M25M |
M28M |
| High Voltage Outputs |
| Typical energy output into 500 Ohms load (Joules) |
3J |
4.6J |
7.6J |
13.8J 150 Ohm |
2J |
3.7J |
3.7J |
4.8J |
7.6J |
4.8J |
7.6J |
4.8J |
7.6J |
| Output Voltage into an open circuit |
9000V |
9000V |
9600V |
9000V |
7400V |
8000V |
8000V |
8500V |
9300V |
8500V |
9300V |
8500V |
9300V |
| High or Low Voltage modes, alarm monitoring is enabled in both modes |
Yes |
Yes |
Yes |
Yes |
Fixed |
Fixed |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Output voltage settings can be changed for both the High and the Low voltage modes |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Number of High Voltage monitored zones |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
2 |
2 |
2 |
2 |
| Number of Earth loop monitored zones |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
2 |
2 |
2 |
2 |
| Adaptive Power Technology (APT), reducing false alarms and arcing on the fence |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
No |
No |
No |
No |
No |
| Fence Interference detection from foreign energizers |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
No |
No |
No |
| Energizer Controls and Displays |
| Keypads for the remote control of the energizer |
2 max |
2 max |
2 max |
2 max |
No |
No |
4 max 1 incl |
4 max |
4 max |
4 max |
4 max |
4 max |
4 max |
| Tag switch - to control the energizer without using a keypad |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Remote On/Off input |
Yes* |
Yes* |
Yes* |
Yes* |
Yes* |
Yes* |
Yes* |
Yes* |
Yes* |
Yes* |
Yes* |
Yes* |
Yes* |
| Displays the output and return voltages |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
No |
No |
No |
No |
No |
| Display type |
LCD |
LCD |
LCD |
LCD |
LED |
LED |
LED |
LED |
LED |
LED |
LED |
LED |
LED |
| Gate and Panic Button inputs |
| Timed gate switch input, used to monitor open and closing of the gate |
Yes* |
Yes* |
Yes* |
Yes* |
Yes* |
Yes* |
Yes* |
Yes* |
Yes* |
Yes* |
Yes* |
Yes* |
Yes* |
| Panic button input |
Yes* |
Yes* |
Yes* |
Yes* |
Yes* |
Yes* |
Yes* |
Yes* |
Yes* |
Yes* |
Yes* |
Yes* |
Yes* |
| Alarm outputs |
| Siren output, time programmable |
Yes |
Yes |
Yes |
Yes |
Fixed |
Fixed |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Strobe light output to visually indicate an alarm condition |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
2 |
2 |
2 |
2 |
| Power supply and battery backup systems |
| Mains supply voltage*** |
230V |
230V |
230V |
230V |
230V |
230V |
230V |
230V |
230V |
230V |
230V |
230V |
230V |
| Typical power consumption under normal operating conditions |
18VA |
18VA |
25VA |
17VA |
17VA |
18VA |
16VA |
27VA |
23VA |
27VA |
25VA |
27VA |
25VA |
| Internal battery backup system in case of power failure, capacity of battery |
7 Ah |
7 Ah |
7 Ah |
7 Ah |
7 Ah |
7 Ah |
7 Ah |
7 Ah |
7 Ah |
7 Ah |
7 Ah |
7 Ah |
7 Ah |
| Typical standby time, with a fully charged battery |
24 hrs |
24 hrs |
24 hrs |
9 hrs |
24 hrs |
36 hrs |
24 hrs |
6 hrs |
8 hrs |
7 hrs |
6 hrs |
7 hrs |
6 hrs |
| Solar power panels can be connected to power the energizers, (recommend Watt size for 24 hr operation)** |
60 Watts |
60 Watts |
140 Watts |
140 Watts |
. |
60 Watts |
60 Watts |
120 Watts |
140 Watts |
120 Watts |
140 Watts |
120 Watts |
140 Watts |
| Solar voltage regulator |
5 Amp |
5 Amp |
10 Amp |
10 Amp |
. |
5 Amp |
5 Amp |
9 Amp |
10 Amp |
9 Amp |
10 Amp |
9 Amp |
10 Amp |
| Deep cycle battery size recommended in Amp hours (20 % discharge over a 24 hr cycle |
60 Ah |
60 Ah |
150 Ah |
150 Ah |
. |
60 Ah |
60 Ah |
120 Ah |
150 Ah |
120 Ah |
150 Ah |
120 Ah |
150 Ah |
| Druid 114 maintains a voltage of 5 600 V into a 100 Ohm load at 13.4 J and the voltage is at 7 100 V at a maximum of 13.8 J output into a 150 Ohm load |
| Wire length per energizer (live wires in a series system) for both solid and stranded wires |
| Nemtek Energizer Brand |
Druid |
Wizord |
Merlin |
Merlin Stealth |
Stealth Master |
| Galvanised wires, 1.2mm |
| Optimal performance up to |
3km |
5km |
10km |
15km |
2km |
3km |
3km |
8km |
10km |
2x4km |
2x5km |
2x4km |
2x5km |
| Maximum |
5km |
8km |
25km |
35km |
4km |
5km |
5km |
18km |
25km |
2x9km |
2x13km |
2x9km |
2x13km |
| Galvanised wires, 2.0 mm, 2.24 mm |
| Optimal performance up to |
3.3km |
5km |
20km |
20km |
3km |
4km |
4km |
16km |
20km |
2x8km |
2x10km |
2x8km |
2x10km |
| Maximum |
6.6km |
12km |
50km |
50km |
6km |
10km |
10km |
35km |
50km |
2x17km |
2x25km |
2x17km |
2x25km |
| Stainless Steel 1.0 mm, 304 and 316 grade |
| Optimal performance up to |
0.6km |
0.7km |
0.8km |
0.9km |
0.5km |
0.6km |
3km |
0.6km |
0.7km |
2x0.7km |
2x0.8km |
2x0.7km |
2x0.8km |
| Maximum |
0.9km |
1km |
1km |
1.2km |
0.6km |
5km |
0.9km |
0.9km |
1km |
2x1km |
2x1.2km |
2x1km |
2x1.2km |
| Stainless Steel 1.2 mm, 304 and 316 grade |
| Optimal performance up to |
0.7km |
0.8km |
1km |
1km |
0.6km |
0.7km |
0.7km |
0.8km |
1km |
2x0.8km |
2x1km |
2x0.8km |
2x1km |
| Maximum |
1km |
1.1km |
1.3km |
1.3km |
0.9km |
1km |
1km |
1.1km |
1.3km |
2x1.1km |
2x1.3km |
2x1.1km |
2x1.3km |
| Stainless Steel 1.6 mm, 304 and 316 grade |
| Optimal performance up to |
1.4km |
1.6km |
2km |
2km |
1.2km |
1.4km |
1.4km |
1.6km |
2km |
2x1.6km |
2x2km |
2x1.6km |
2x2km |
| Maximum |
2km |
2.2km |
2.6km |
2.6km |
1.8km |
2km |
2km |
2.2km |
2.6km |
2x2.2km |
2x2.6km |
2x2.2km |
2x2.6km |
| Stainless Steel 2.0 mm, 304 and 316 grade |
| Optimal performance up to |
2.1km |
2.4km |
3.3km |
3km |
1.8km |
2.1km |
2.1km |
2.4km |
3.3km |
2x2.4km |
2x3km |
2x2.4km |
2x3km |
| Maximum |
3km |
3.3km |
3.9km |
3.9km |
2.7km |
3km |
3km |
3.3km |
3.9km |
2x3.3km |
2x3.9km |
2x3.3km |
2x3.9km |
| Aluminium Wire 1.6 mm and 2.0 mm |
| Optimal performance up to |
8km |
10km |
40km |
40km |
6km |
8km |
8km |
32km |
40km |
2x16km |
2x20km |
2x16km |
2x20km |
| Maximum |
16km |
20km |
80km |
80km |
12km |
16km |
16km |
60km |
80km |
2x30km |
2x40km |
2x30km |
2x40km |
| Multi energizer systems |
| Using the Stealth Master system, per Master |
 |
 |
 |
 |
 |
 |
 |
 |
 |
up to 9 |
up to 9 |
 |
 |
| Using the Sage system and the Nemtek Fence Probe software, number of energizers per Sage |
 |
 |
 |
 |
 |
 |
 |
up to 32 |
up to 32 |
up to 32 |
up to 32 |
 |
 |
| Using the Proxy controller and Cortech software, number of energizers per Proxy |
 |
 |
 |
 |
 |
 |
 |
up to 32 |
up to 32 |
up to 32 |
up to 32 |
 |
 |
| Compliance |
| IEC 60335-2-76 |
yes |
yes |
yes |
yes |
yes |
yes |
yes |
yes |
yes |
yes |
yes |
yes |
yes |
| Cispr 14, EN 61000 |
yes |
yes |
yes |
yes |
yes |
yes |
yes |
yes |
yes |
yes |
yes |
yes |
yes |